<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Filtration Valves Archives | Aquamat</title>
	<atom:link href="https://aquamat.co.za/product-category/filtration-valves/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquamat.co.za/product-category/filtration-valves/</link>
	<description>Over 50 years, yielding successful water management solutions such as Rain &#038; Grey Water Solutions, Wastewater Treatment, Mobile Packaged Water Treatment Plants for Emergency &#038; Disaster Management, wholesale supply of quality components and so much more.</description>
	<lastBuildDate>Wed, 28 May 2025 09:42:08 +0000</lastBuildDate>
	<language>en-ZA</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://aquamat.co.za/wp-content/uploads/2023/04/cropped-Aquamat-Favicon-32x32.png</url>
	<title>Filtration Valves Archives | Aquamat</title>
	<link>https://aquamat.co.za/product-category/filtration-valves/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Automatic Control Valves</title>
		<link>https://aquamat.co.za/product/automatic-control-valves/</link>
		
		<dc:creator><![CDATA[kirst]]></dc:creator>
		<pubDate>Thu, 22 May 2025 13:22:48 +0000</pubDate>
				<guid isPermaLink="false">https://aquamat.co.za/?post_type=product&#038;p=4435</guid>

					<description><![CDATA[<p>Water Filtration Vessels are suitable to be used with all media generally utilised in the filtration process. Certain units are fitted with multi-port valves (sold separately), which have fittings of 1.5 inch to 4 inches.</p>
<p>The post <a href="https://aquamat.co.za/product/automatic-control-valves/">Automatic Control Valves</a> appeared first on <a href="https://aquamat.co.za">Aquamat</a>.</p>
]]></description>
										<content:encoded><![CDATA[
		<div id="fws_6941b8d174d73"  data-column-margin="default" data-midnight="dark"  class="wpb_row vc_row-fluid vc_row top-level"  style="padding-top: 0px; padding-bottom: 0px; "><div class="row-bg-wrap" data-bg-animation="none" data-bg-animation-delay="" data-bg-overlay="false"><div class="inner-wrap row-bg-layer" ><div class="row-bg viewport-desktop"  style=""></div></div></div><div class="row_col_wrap_12 col span_12 dark left">
	<div  class="vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding inherit_tablet inherit_phone "  data-padding-pos="all" data-has-bg-color="false" data-bg-color="" data-bg-opacity="1" data-animation="" data-delay="0" >
		<div class="vc_column-inner" >
			<div class="wpb_wrapper">
				
<div class="wpb_text_column wpb_content_element " >
	<div class="wpb_wrapper">
		<table>
<tbody>
<tr>
<td rowspan="4"><strong>Electrical</strong></td>
<td>Inlet/Outlet Fittings</td>
<td colspan="2">3⁄4” to 1.5” NPS</td>
</tr>
<tr>
<td>Cycles</td>
<td colspan="2">up to 6</td>
</tr>
<tr>
<td>Valve Material</td>
<td colspan="2">Noryl (1) or equivalent</td>
</tr>
<tr>
<td>Regeneration</td>
<td colspan="2">downflow</td>
</tr>
<tr>
<td rowspan="4"><strong>Flow Rates</strong></td>
<td>Service @15 psi drop<br />
(includes bypass)</td>
<td colspan="2">27 gpm</td>
</tr>
<tr>
<td>Backwash @ 25 psi drop<br />
(includes bypass)</td>
<td colspan="2">27 gpm Cv Service</td>
</tr>
<tr>
<td>Cv Service</td>
<td colspan="2">7</td>
</tr>
<tr>
<td>Cv Backwash</td>
<td colspan="2">5.4</td>
</tr>
<tr>
<td><strong>Operating Pressures</strong></td>
<td>Minimum/Maximum</td>
<td colspan="2">20 psi – 125 psi</td>
</tr>
<tr>
<td><strong>Operating</strong><br />
<strong>Temperatures</strong></td>
<td>Minimum/Maximum</td>
<td colspan="2">40o – 110o F</td>
</tr>
<tr>
<td rowspan="6"><strong>Dimensions &amp; Weight</strong></td>
<td>Distributor Pilot</td>
<td colspan="2">1.050” OD Pipe (3⁄4” NPS)</td>
</tr>
<tr>
<td>Drain Line</td>
<td colspan="2">3⁄4” or 1” NPT</td>
</tr>
<tr>
<td>Brine Line</td>
<td colspan="2">3/8” or 1⁄2” OD Poly Tube</td>
</tr>
<tr>
<td>Mounting Base</td>
<td colspan="2">2 1⁄2” – 8 NPSM</td>
</tr>
<tr>
<td>Height From Top Of Tank</td>
<td colspan="2">7 3/8” Weight</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">4.5 lbs.</td>
</tr>
<tr>
<td rowspan="5"><strong>Electrical</strong><br />
<strong>Specifications</strong></td>
<td></td>
<td>US</td>
<td>International</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>120V AC</td>
<td>230V AC</td>
</tr>
<tr>
<td>Supply Frequency</td>
<td>60 Hz</td>
<td>50 Hz</td>
</tr>
<tr>
<td>Output Voltage</td>
<td>12V AC</td>
<td>12V AC</td>
</tr>
<tr>
<td>Output Current</td>
<td>500 mA</td>
<td>500 mA</td>
</tr>
<tr>
<td rowspan="2"><strong>Tank Applications</strong></td>
<td>Water Softener</td>
<td colspan="2">6” – 21” diameter</td>
</tr>
<tr>
<td>Water Filter (2)</td>
<td colspan="2">6” – 21” diameter</td>
</tr>
</tbody>
</table>
	</div>
</div>




			</div> 
		</div>
	</div> 
</div></div>
<p>The post <a href="https://aquamat.co.za/product/automatic-control-valves/">Automatic Control Valves</a> appeared first on <a href="https://aquamat.co.za">Aquamat</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Manual Filter Valves for FRP Vessels</title>
		<link>https://aquamat.co.za/product/manual-filter-valves-for-frp-vessels/</link>
		
		<dc:creator><![CDATA[kirst]]></dc:creator>
		<pubDate>Thu, 22 May 2025 13:19:44 +0000</pubDate>
				<guid isPermaLink="false">https://aquamat.co.za/?post_type=product&#038;p=4433</guid>

					<description><![CDATA[<p>Water Filtration Vessels are suitable to be used with all media generally utilised in the filtration process. Certain units are fitted with multi-port valves (sold separately), which have fittings of 1.5 inch to 4 inches.</p>
<p>The post <a href="https://aquamat.co.za/product/manual-filter-valves-for-frp-vessels/">Manual Filter Valves for FRP Vessels</a> appeared first on <a href="https://aquamat.co.za">Aquamat</a>.</p>
]]></description>
										<content:encoded><![CDATA[
		<div id="fws_6941b8d177172"  data-column-margin="default" data-midnight="dark"  class="wpb_row vc_row-fluid vc_row"  style="padding-top: 0px; padding-bottom: 0px; "><div class="row-bg-wrap" data-bg-animation="none" data-bg-animation-delay="" data-bg-overlay="false"><div class="inner-wrap row-bg-layer" ><div class="row-bg viewport-desktop"  style=""></div></div></div><div class="row_col_wrap_12 col span_12 dark left">
	<div  class="vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding inherit_tablet inherit_phone "  data-padding-pos="all" data-has-bg-color="false" data-bg-color="" data-bg-opacity="1" data-animation="" data-delay="0" >
		<div class="vc_column-inner" >
			<div class="wpb_wrapper">
				
<div class="wpb_text_column wpb_content_element " >
	<div class="wpb_wrapper">
		<table>
<tbody>
<tr>
<td style="text-align: center;" colspan="3"><strong>1’’ F56A Valve</strong></td>
</tr>
<tr>
<td>Water Pressure</td>
<td>0.15-0.6mpa</td>
</tr>
<tr>
<td>Water Temperature</td>
<td>5°c-45°c</td>
</tr>
<tr>
<td>Water Turbidity</td>
<td>&lt;20FTU</td>
</tr>
<tr>
<td>Inlet/Oulet</td>
<td>1”F</td>
</tr>
<tr>
<td>Drain</td>
<td>1”F</td>
</tr>
<tr>
<td>Base</td>
<td>2.5”-8NPSM</td>
</tr>
<tr>
<td>Riser Pipe</td>
<td>1.05”OD</td>
</tr>
<tr>
<td>Flow Rate</td>
<td>4m3/h</td>
</tr>
</tbody>
</table>
	</div>
</div>




<div class="wpb_text_column wpb_content_element " >
	<div class="wpb_wrapper">
		<table>
<tbody>
<tr>
<td style="text-align: center;" colspan="2"><strong>1” F56E Valve</strong></td>
</tr>
<tr>
<td>Inlet/Outlet</td>
<td>1/2”</td>
</tr>
<tr>
<td>Drain</td>
<td>1/2”</td>
</tr>
<tr>
<td>Central Pipe</td>
<td>1.05”</td>
</tr>
<tr>
<td>Base</td>
<td>2.5”-8UN</td>
</tr>
<tr>
<td>Flow Rate</td>
<td>maximum 2m3/h</td>
</tr>
<tr>
<td>Tank</td>
<td>6”-10” FRP Tank</td>
</tr>
<tr>
<td>Operation Ratings</td>
<td></td>
</tr>
<tr>
<td>Working Pressure</td>
<td>0.15-0.6Mpa</td>
</tr>
<tr>
<td>Working Temperature</td>
<td>5-50°C</td>
</tr>
</tbody>
</table>
	</div>
</div>




<div class="wpb_text_column wpb_content_element " >
	<div class="wpb_wrapper">
		<table>
<tbody>
<tr>
<td style="text-align: center;" colspan="2"><strong>2” F56d Valve</strong></td>
</tr>
<tr>
<td>Water Pressure</td>
<td>0.15-0.6mpa</td>
</tr>
<tr>
<td>Water Temperature</td>
<td>5°c-45°c</td>
</tr>
<tr>
<td>Water Turbidity</td>
<td>20FTU</td>
</tr>
<tr>
<td>Inlet/Oulet</td>
<td>2”F</td>
</tr>
<tr>
<td>Drain</td>
<td>1.5”F</td>
</tr>
<tr>
<td>Base</td>
<td>4”-8UN</td>
</tr>
<tr>
<td>Riser Pipe</td>
<td>1.05”OD</td>
</tr>
<tr>
<td>Max Flow Rate</td>
<td>10m3/h</td>
</tr>
<tr>
<td>Sutiable Tank Size</td>
<td>10”-24”</td>
</tr>
</tbody>
</table>
	</div>
</div>




			</div> 
		</div>
	</div> 
</div></div>
<p>The post <a href="https://aquamat.co.za/product/manual-filter-valves-for-frp-vessels/">Manual Filter Valves for FRP Vessels</a> appeared first on <a href="https://aquamat.co.za">Aquamat</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
