Ultraviolet Sterilisation Commercial UV’s
Ultraviolet Sterilisers are used in applications where chemicals and other media are not suitable for the use of water treatment or purification. They kill bacteria and also leave no residual product. This solution is also used as a final sterilisation process before distribution and/or use of water. Aquamat boast a wide range of small- footprint, high capacity UV systems manufactured in the Netherlands. Low- and medium-pressure lamps are also available and are CE certified.
Commercial UV’s | |||||
Type | Available Options |
Included Options |
Controller | Capacity* UVT=90% |
Capacity* UVT=95% |
UVME1130L2 | See Options (except UVEEC) | UVEST1 | Lambda 2 | 23,0 | 28,5 |
UVME1250L2 | See Options (except UVEEC) | UVEST1 | Lambda 2 | 31,0 | 37,5 |
UVLE1250L2 | See Options (except UVEEC) | UVEST1 | Lambda 2 | 37,0 | 45,0 |
UVLE2250L2 | See Options (except UVEEC) | UVEST1 | Lambda 2 | 61,0 | 74,5 |
UVLE3250L2 | See Options (except UVEEC) | UVEST1 | Lambda 2 | 91,0 | 112,0 |
UVLE4250L2 | See Options (except UVEEC) | UVEST1, UVETD | Lambda 2 | 121,0 | 149,0 |
UVLE6130L2 | See Options (except UVEEC) | UVEST1, UVETD | Lambda 2 | 182,0 | 223,0 |
UVME1130L5 | See Options | UVEST1 | Lambda 5 | 23,0 | 28,5 |
UVME1250L5 | See Options | UVEST1 | Lambda 5 | 31,0 | 37,5 |
UVLE1250L5 | See Options | UVEST1 | Lambda 5 | 37,0 | 45,0 |
UVLE2250L5 | See Options | UVEST1 | Lambda 5 | 61,0 | 74,50 |
UVLE3250L5 | See Options | UVEST1 | Lambda 5 | 91,0 | 112,0 |
UVLE4250L5 | See Options | UVEST1, UVETD | Lambda 5 | 121,0 | 149,0 |
UVLE6250L5 | See Options | UVEST1, UVETD | Lambda 5 | 182,0 | 223,0 |
UVLE8250L5 | See Options | UVEST1, UVETD | Lambda 5 | 242,0 | 298,0 |
*Capacity in m³/h at 40mJ/cm2 |
Optional Extras | |
Code | Description |
UVEST1 | UV Sensor, type Us1 (External sensor) |
UVEST4 | UV Sensor, type Us4 (internal sensor, not for UVME1 with Mc) |
UVEMCME | Manual anti-fouling mechanism |
UVEMCLE | Manual anti-fouling mechanism |
UVEECME | Electrical anti-fouling mechanism UVME (except for L2) |
UVEECLE | Electrical anti-fouling mechanism UVLE (except for L2) |
UVEPCU/UVEPCZ | Position of connections in U-shape or Z-shape |
UVE1/4C | Extra connection on chamer 1/4” incl, plug |
UVETD | Temperature detector with read-out inside cabinet (for 1-3 lamp systems) |
UVE400V3LN | Power supply 400V 3L + N |
UVE400V3L | Power supply 400V 3L without N |
UVEPS60HZ | Power supply with 60Hz instead of 50Hz |
UVEMOD1-7 | Modbus 1-7 lamp systems |
UVEMOD8+ | Modbus more than 7 lamp systems |
UVEMEPHARMA | pharma execution BME (excl.certificates) |
UVELEPHARMA | pharma execution BLE (excl.certificates) |
UVETE130 | UV Lamp E130 |
UVETE250 | UV Lamp E250 |
UVESQ130 | Quartz Sleeve 37/0696 Q130 (incl. O ring) |
UVESQ250 | Quartz Sleeve 37/1198 Q250 (incl. O ring) |
UVEEBT2 | Electronic ballast E130/E250 (for 2 lamps) |