Aquamat Carbon Filter (ACF) Auto
WATER QUALITY PROBLEM
High-quality premium coconut shell-based activated carbon media reduces chlorine, and organic contaminants, and also corrects the taste and odour of water.
GROUND WATER
SURFACE WATER
MUNICIPAL WATER
Description
Feed water enters the unit and passes through the activated carbon adsorption media where chlorine and dissolved organics are removed. Periodically the media is backwashed to remove any accumulated particulate matter. This process is fully automatic.
Floor-standing reinforced fiberglass cylinder.
A robust long-lasting design.
Premium grade activated carbon media.
Ensures a consistent supply of quality water.
Clack Automatic Timer Control
The backwashing process is initiated by the elapsed time since the last backwash
Feed water bypass to service during backwash –
Provides a continuous supply of water even during the backwashing process
- Easy to operate, supplied with an automatic backwasing valve
- The range accommodates flow rates up to 10m3/hour
- Higher flow rates can be achieved through parallel configuration
- Coconut Shell based activated carbon is very durable so losses due to attrition are kept to a minimum
- Media replacement recommended in 2/3 years (Dependent on frequency of backwasing, site conditions and water quality)
Required Services | |
Electrical ** | 220v ,50Hz |
Feed water pressure | 2 – 7 Bar |
Feed water temperature | 1 – 43∈C |
Drain | Sized to accommodate backwash flow rate |

Conditions for Operation | Range | Supplementary products |
Water pH | 5,0 – 11 | . |
Max. Water Temp | 43ºC | . |
Suspended Matter | None | ASF |
Mineral Oil | None | DAF |
Minimum Inlet Pressure | 200 kPa (2 Bar) | Booster pump |
Maximum Inlet Pressure | 700 kPa (7 Bar) | Pressure Regulating Valve |
Vacuum | Not Permitted | . |
Model Name | ACF10 | ACF13 | ACF14 | ACF16 | ACF18 | ACF21 | ACF24 | ACF30 | ACF36 |
Flow rates [M3/hr] | |||||||||
Maximum Service @ 8 Minutes Contact Time | 0,65 | 1,10 | 1,58 | 2 | 2,70 | 3,50 | 5,25 | 7,70 | 10,9 |
Maximum Service @ 12 Minutes Contact Time | 0,41 | 0,71 | 0,99 | 1,26 | 1,71 | 2,20 | 3,29 | 4,80 | 6,82 |
Pressure Drop @ Max Service Flow (bar) | 0,28 | 0,28 | 0,28 | 0,28 | 0,28 | 0,28 | 0,28 | 0,28 | 0,28 |
Regeneration | |||||||||
Backwash Flowrate (m3/hr/m²) | 24,46 | 24,46 | 24,46 | 24,46 | 24,46 | 24,46 | 24,46 | 24,46 | 24,46 |
Backwash Flowrate (m3/hr) | 1,30 | 2,20 | 3,20 | 4,00 | 5,40 | 7,00 | 10,50 | 15,40 | 21,80 |
Effluent Volume (m3) – 6 min Backwash Time | 0,13 | 0,22 | 0,32 | 0,40 | 0,54 | 0,70 | 1,05 | 1,54 | 2,18 |
Connections – BSP (inches) | |||||||||
Inlet | 1 | 1 | 1 | 1 | 1,5 | 1,5 | 2 | 2 | 2 |
Outlet | 1 | 1 | 1 | 1 | 1,5 | 1,5 | 2 | 2 | 2 |
Drain | 1 | 1 | 1 | 1 | 1,5 | 1,5 | 2 | 2 | 2 |
Dimensions (mm) | |||||||||
Height (Inc. Control Valve) | 1381 | 1398 | 1674 | 1706 | 1722 | 1721 | 1918 | 2140 | 2150 |
Diameter | 268 | 335 | 366 | 411 | 491 | 555 | 611 | 781 | 932 |
Weight (kg) | |||||||||
Vessel | 8 | 11 | 15 | 19,47 | 33 | 33 | 44,1 | 79,5 | 100,5 |
Working | 53 | 81 | 85 | 209,47 | 303 | 303 | 364,1 | 439,5 | 550,5 |